Vanadium content of Steel and cast iron
Release Time
2024-11-22 08:42
The REX Ti-50 Automatic Potential Titrator allows quick and simple determinations of the vanadium content of steel and cast iron by potentiometric titration.

1. Standard Reference
ISO 4947-2020 《Steel and cast iron-Determination of Vanadium content -Potentiometric titration method》
2. The Principle
Dissolution of a test portion with appropriate acids. Addition of hydrofluoric acid to keep tungstenin solution.
Oxidation of chromium and vanadium by potassium peroxydisulfate. Partial oxidation of chromium.
While checking the potential of the solution:
- reduction of chromium(Vl) and vanadium(V) by ammonium iron(ll) sulfate;
- oxidation of vanadium by a slight excess of potassium permanganate, reduction of the excess of permanganate by sodium nitrite, and reduction of the excess of sodium nitrite by sulfamic acid.
Potentiometric titration of vanadium with an ammonium ironll sulfate standard solution.
3. Recommended Configuration
- Ti-50 Automatic Potential Titrator
- Range:(-2000.00~2000.00) mV
- mV Accuracy:±0.03% or ±0.2mV
- 1 extra burette driver can be installed (optional).
- Replaceable burette with high-accuracy (10 ml or 20 ml selectable).
- Support acid-base titration, non-aqueous aqueous phase titration, constant titration, REDOX titration, precipitation titration, complexation titration
- Support the following titration modes: DET (dynamic equivalence point titration), MET (monotone equivalence point titration), SET (Preset Endpoint Titration) and MAT (manual titration).
- Titration methods, curves and results are displayed in detail.
- Includes 213-01 platinum electrode and 232-01 reference electrode.

- Auxiliary titration unit 20mL
- Burette valve device 20mL (SC5.461.057)
- Anti-diffusion capillary
- Electrodes
- 213-01 Platinum electrode
- 232-01 Reference electrode(Saturated KCl)

|
Model |
213-01 |
|
Name |
Platinum electrode |
|
Connector Type |
BNC(Q9) |
|
Sensor material |
Glass |
|
Dimensions |
Φ12×120mm |
|
Measuring unit material |
Platinum |
|
Working Temperature |
5~50 ℃ |
|
Application |
REDOX Titration |

|
Model |
232-01 |
|
Name |
Reference electrode |
|
Type of electrode |
Saturated single-junction calomel electrode |
|
Connector Type |
U shape terminal |
|
Fill Solution |
Saturated KCl solution |
|
junction material |
ceramic |
|
Sensor material |
Glass |
|
Dimensions |
Φ12×120 mm |
|
Working Temperature |
5~55 ℃ |
4. Titration Setting
- REDOX titration
- Sample for total content of vanadium and chromium: DET (dynamic equivalence point titration)
- Sample for content of vanadium : MET (monotone equivalence point titration)
- Blank Sample for total content of vanadium and chromium: MET (monotone equivalence point titration)
5. Titration curve

The titration curve of the total content of vanadium and chromium

The titration curve of vanadium content
PRECISION PERFECT
Contact Us
-
Tel:0086-021-39506429/39506392
Mail:info@lei-ci.com
-
Fax: 0086-021-39506398
Contact