图片名称

M600L Multi-parameter Analyzer

+
  • M600L-2025(1776652590407).jpg

We will contact you within one working day. Please pay attention to your email.

Submit

Features

GENERAL FEATURES

  • Color High contrast LCD touchscreen, 7.0 inches.
  • Temperature Unit Options: Choose between ºC or °F.
  • Reset feature automatically resumes all settings back to factory default options.
  • IP54 waterproof.

 

Professional-Moldable, Multi-channel

  • Modular four Channel: Four measurements channels can be configured in any combination of the modules.
  • Standard configuration: 4 RES modules. Support the expansion of other modules, such as pH module, pX module, EC-T module, EC-F module, DO-F module, DO-P module.
  • Support for 6 modules: pH module, pX module, EC-T module, EC-F module, DO-F module, DO-P module
  • The multi-channel allows measurements of 1, 2, 3, or 4 parameters simultaneously, either in the same or in different samples. 
  • According to the module, the parameters can be pH, mV, EC, Resistivity, TDS, Sal., ISE, pX, DO, DO Saturation and Temp.

Smart operation, Auto-recognition, High throughput

  • Intelligent operating system, with user management, method management, method management, sample management, electrode management, data management, GMP management and other functions.
  • User three-level authority management and password management.
  • Method management function, built-in 16 methods and custom measurement methods.
  • Multi-reading feature allows auto-read, timed-read and continuous-read. 
  • Calibration reminder and forced calibration function.
  • Verification reminder and forced verification function. 
  • Calibration and measurement alarm limit setting.
  • Connection with automatic sampler to realize the automatic measurement and batch detection of samples.

Data management, Audit trial

  • Data Storage 1000 sets of each parameter (GLP-compliant).
  • Support for GMP management, the GMP logs achieve the tracking and analysis of the the data (compliant with FDA 21 CFR Part 11 ).
  • RS-232 communication for print and the print format can be alternate.
  • USB communication for PC software.
  • USB drive for method export and import.
  • USB drive for data export with CSV or PDF format.
  • USB Barcode Scanner Support.

 

pH module(2026)

  • It shows the mV, pH and ORP.
  • 1-6 points pH/pX calibration. 1 point ORP calibration.
  • NIST, USA, MERK, GB, DIN, JIS or GOST pH buffers standard recognition.
  • Data storage of 1000 sets of pH measurement results, 100 sets of calibration data, and 1000 sets of pH standard solution verification data.

 

pX module(2026)

  • It shows the mV, pH, pX, ORP and ion concentration.
  • Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm and ppb.²
  • Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
  • Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.
  • 1-6 points pH/pX calibration. 1 point ORP calibration.
  • NIST, USA, MERK, GB, DIN, JIS or GOST pH buffers standard recognition.
  • Data storage of 1000 sets of pH/ORP/Ion measurement results, 100 sets of calibration data, and 1000 sets of pH standard solution verification data.

 

EC-T module(2026)

  • It shows conductivity, Resistivity, TDS, Salinity and Ash.
  • 1-5 points calibration with GB and International standard recognition.
  • Temperature compensation type (none, linear, pure water).
  • Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.
  • Data storage of 1000 sets of EC/Resistivity/TDS/Salinity/Ash measurement results, 100 sets of calibration data, and 1000 sets of EC standard solution verification data.

 

 

EC-F module(2026)

  • It shows conductivity, Resistivity, TDS, and Salinity.
  • 1-5 points calibration with GB and International standard recognition.
  • Temperature compensation type (none, linear, pure water).
  • Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.
  • Data storage of 1000 sets of EC/Resistivity/TDS/Salinity/Ash measurement results, 100 sets of calibration data, and 1000 sets of EC standard solution verification data.

 

DO-P module(2026)

  • It is a polarographic dissolved oxygen module.
  • Support for air-saturated water or zero oxygen calibration.
  • Auto barometric pressure compensation. 
  • Manual Salinity Factor Correction.
  • Selectable pressure unit, including kPa, mbar, Torr, Atm.
  • Data storage of 1000 sets of DO/Saturation measurement results, 100 sets of calibration data, and 1000 sets of Zero DO and Full DO verification data.

 

DO-F module(2026)

  • It is an optical dissolved oxygen module.
  • Support for air-saturated water or zero oxygen calibration.
  • Auto barometric pressure compensation. 
  • Manual Salinity Factor Correction.
  • Selectable pressure unit, including kPa, mbar, Torr, Atm.
  • Data storage of 1000 sets of DO/Saturation measurement results, 100 sets of calibration data, and 1000 sets of Zero DO and Full DO verification data.

Specifications

Module

pH module

mV

Range

(-2000.00~2000.00)mV

 

Resolution

1mV, 0.1mV, 0.01mV

 

Accuracy

±0.03% or ±0.1mV

pH

Range

(-2.000~20.000)pH

 

Resolution

0.1pH, 0.01pH, 0.001pH

 

Accuracy

±0.002pH

Temperature

Range

(-10.0135.0)ºC, (14.0~275.0)ºF

 

Resolution

0.1ºC, 0.1ºF

 

Accuracy

±0.3ºC (0.0~60.0)ºC±1.0 ºC (Other Range)

Module

pX module

mV

Range

(-2000.00~2000.00)mV

 

Resolution

1mV, 0.1mV, 0.01mV

 

Accuracy

±0.03% or ±0.1mV

pH

Range

(-2.000~20.000)pH

 

Resolution

0.001pH

 

Accuracy

±0.002pH

pX

Range

(-2.000~20.000)pX

 

Resolution

0.001pX

 

Accuracy

±0.002pX

Ion

Range

(1.000e-9 ~ 9.999e+9), 

Unit: mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb

 

Resolution

Up to 4 significant digits

 

Accuracy

±0.3%

Temperature

Range

(-10.0135.0)ºC, (14.0~275.0)ºF

 

Resolution

0.1ºC, 0.1ºF

 

Accuracy

±0.3ºC (0.0~60.0)ºC±1.0 ºC (Other Range)

Module

EC-T module

Conductivity

Range

0.000μS/cm~3000mS/cm

 

Resolution

0.001μS/cm minimum, changed with range

 

Accuracy

±0.5%FS

 

Repeatability

0.40%FS

Resistivity

Range

5.00Ω·cm~100.0MΩ·cm

 

Resolution

0.01Ω·cm minimum, changed with range

 

Accuracy

±0.5%FS

TDS

Range

0.000 ppm~1000ppt

 

Resolution

0.001ppm minimum, changed with range

 

Accuracy

±0.5%FS

Salinity

Range

(0.080.0) ppt, (0.00~8.00) %NaCl, (2.00042.000)psu

 

Resolution

0.1ppt, 0.1%NaCl, 0.001psu

 

Accuracy

±1ppt

Temperature

Range

(-10.0135.0)ºC, (14.0~275.0)ºF

 

Resolution

0.1ºC, 0.1ºF

 

Accuracy

±0.3ºC (0.0~60.0)ºC±1.0 ºC (Other Range)

Module

EC-F module

Conductivity

Range

50.0μS/cm~3000mS/cm

 

Resolution

0.001μS/cm minimum, changed with range

 

Accuracy

±1.5%FS

Resistivity

Range

5.00Ω·cm~20.0kΩ·cm

 

Resolution

0.01Ω·cm minimum, changed with range

 

Accuracy

±1.5%FS

TDS

Range

25.0 ppm~1000 ppt

 

Resolution

0.001ppm minimum, changed with range

 

Accuracy

±1.5%FS

Salinity

Range

(0.080.0) ppt, (0.00~8.00) %NaCl, (2.00042.000)psu

 

Resolution

0.1ppt, 0.1%NaCl, 0.001psu

 

Accuracy

±2ppt

Temperature

Range

(-10.0135.0)ºC, (14.0~275.0)ºF

 

Resolution

0.1ºC, 0.1ºF

 

Accuracy

±0.5ºC(0.0ºC~60.0ºC)±1.5ºC (Other Range)

Module

DO-P module

Dissolved

Oxygen Concentration

Range

(0.00~99.99) ppm

 

Resolution

0.01ppm

 

Accuracy

±0.10ppm, (0.00~50.00)ppm

±0.50ppm, (50.0~99.99)ppm

 

Repeatability

0.15ppm

 

Zero Accuracy

≤0.1ppm

 

Instrument Accuracy

≤20.00ppm: ±0.30 ppm

20.00ppm: ±10.0%

 

Response time

≤45s(20ºC up to 90% response)

 

Salinity Accuracy

±2%

Saturation

Range

(0.0~600.0)%

 

Resolution

0.10%

 

Accuracy

±2.0%

Temperature

Range

(-10.0135.0)ºC, (14.0~275.0)ºF

 

Resolution

0.1ºC, 0.1ºF

 

Accuracy

±0.3ºC (0.0~60.0)ºC±1.0 ºC (Other Range)

Module

DO-F module

Dissolved

Oxygen Concentration

Range

(0.00~20.00)ppm

 

Resolution

0.01ppm

 

Repeatability

0.15ppm

 

Zero Accuracy

≤0.1ppm

 

Instrument Accuracy

±0.30 ppm

 

Response time

≤60s(20ºC, up to 90% response)

 

Salinity Accuracy

±2%

Saturation

Range

(0.0~200.0)%

 

Resolution

0.10%

 

Accuracy

±10.0%

Temperature

Range

(0.050.0)ºC, (32.0122.0)ºF

 

Resolution

ºC, ºF

 

Accuracy

±0.3ºC (0.0~50.0)ºC